Commit a51cf20c authored by Howard Chu's avatar Howard Chu
Browse files

ITS#4026 add -F description for all tools

parent 5fd0e53b
......@@ -8,6 +8,7 @@ slapacl \- Check access to a list of attributes.
.B [\-v]
.B [\-d level]
.B [\-f slapd.conf]
.B [\-F confdir]
.B [\-D authcDN | \-U authcID]
.B \-b DN
.B [\-u]
......@@ -46,6 +47,19 @@ specify an alternative
.BR slapd.conf (5)
file.
.TP
.BI \-F " confdir"
specify a config directory.
If both
.B -f
and
.B -F
are specified, the config file will be read and converted to
config directory format and written to the specified directory.
If neither option is specified, an attempt to read the
default config directory wll be made before trying to use the default
config file. If a valid config directory exists then the
default config file is ignored.
.TP
.BI \-D " authcDN"
specify a DN to be used as identity through the test session
when selecting appropriate
......
......@@ -15,6 +15,7 @@ slapadd \- Add entries to a SLAPD database
.B [\-b suffix]
.B [\-n dbnum]
.B [\-f slapd.conf]
.B [\-F confdir]
.B [\-l ldif-file]
.SH DESCRIPTION
.LP
......@@ -85,6 +86,20 @@ specify an alternative
.BR slapd.conf (5)
file.
.TP
.BI \-F " confdir"
specify a config directory.
If both
.B -f
and
.B -F
are specified, the config file will be read and converted to
config directory format and written to the specified directory.
If neither option is specified, an attempt to read the
default config directory wll be made before trying to use the default
config file. If a valid config directory exists then the
default config file is ignored. If dryrun mode is also specified,
no conversion will occur.
.TP
.BI \-l " ldif-file"
Read LDIF from the specified file instead of standard input.
.SH LIMITATIONS
......
......@@ -8,6 +8,7 @@ slapauth \- Check a list of string-represented IDs for authc/authz.
.B [\-v]
.B [\-d level]
.B [\-f slapd.conf]
.B [\-F confdir]
.B [\-M mech]
.B [\-R realm]
.B [\-U authcID]
......@@ -44,6 +45,19 @@ specify an alternative
.BR slapd.conf (5)
file.
.TP
.BI \-F " confdir"
specify a config directory.
If both
.B -f
and
.B -F
are specified, the config file will be read and converted to
config directory format and written to the specified directory.
If neither option is specified, an attempt to read the
default config directory wll be made before trying to use the default
config file. If a valid config directory exists then the
default config file is ignored.
.TP
.BI \-M " mech"
specify a mechanism.
.TP
......
......@@ -14,6 +14,7 @@ slapcat \- SLAPD database to LDIF utility
.B [\-a filter]
.B [\-s subtree-dn]
.B [\-f slapd.conf]
.B [\-F confdir]
.B [\-l ldif-file]
.B
.LP
......@@ -87,6 +88,19 @@ Specify an alternative
.BR slapd.conf (5)
file.
.TP
.BI \-F " confdir"
specify a config directory.
If both
.B -f
and
.B -F
are specified, the config file will be read and converted to
config directory format and written to the specified directory.
If neither option is specified, an attempt to read the
default config directory wll be made before trying to use the default
config file. If a valid config directory exists then the
default config file is ignored.
.TP
.BI \-l " ldif-file"
Write LDIF to specified file instead of standard output.
.SH LIMITATIONS
......
......@@ -41,6 +41,19 @@ specify an alternative
.BR slapd.conf (5)
file.
.TP
.BI \-F " confdir"
specify a config directory.
If both
.B -f
and
.B -F
are specified, the config file will be read and converted to
config directory format and written to the specified directory.
If neither option is specified, an attempt to read the
default config directory wll be made before trying to use the default
config file. If a valid config directory exists then the
default config file is ignored.
.TP
.BI \-N
only output a normalized form of the DN, suitable to be used
in a normalization tool; incompatible with
......
......@@ -13,6 +13,7 @@ slapindex \- SLAPD index to LDIF utility
.B [\-b suffix]
.B [\-n dbnum]
.B [\-f slapd.conf]
.B [\-F confdir]
.B
.LP
.SH DESCRIPTION
......@@ -63,6 +64,19 @@ option.
specify an alternative
.BR slapd.conf (5)
file.
.TP
.BI \-F " confdir"
specify a config directory.
If both
.B -f
and
.B -F
are specified, the config file will be read and converted to
config directory format and written to the specified directory.
If neither option is specified, an attempt to read the
default config directory wll be made before trying to use the default
config file. If a valid config directory exists then the
default config file is ignored.
.SH LIMITATIONS
Your
.BR slapd (8)
......
......@@ -45,8 +45,7 @@ If neither option is specified, slaptest will attempt to read the
default config directory before trying to use the default
config file. If a valid config directory exists then the
default config file is ignored. If dryrun mode is also specified,
no conversion will occur. All of the slap tools that
use the config options observe this same behavior.
no conversion will occur.
.TP
.B \-u
enable dryrun mode (i.e. don't fail if databases cannot be opened,
......
Supports Markdown
0% or .
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment